UPS Battery

Brochure

Kokams K-UPS battery provides optimal protection against outages for a number of applications including medical, telecom, and data centers. During an outage, our UPS battery immediately provides battery backup power to protect mission critical information and systems.

KOKAM BATTERY SYSTEM

TECHNICAL OVERVIEW OF OUR LITHIUM ION BATTERY RACK

  • 2 Pole – Ultra High Power

    2 Pole – Ultra High Power

    Item Specification Remarks
    Backup Time Up to 6 minutes Recommended
    Model No. 132S 140S 160S
    Configuration 1P22S x 6 1P20S x 7 1P20S x 8 Cell: SLPB130255255P (75Ah)
    Installed Energy 36.6kWh 38.8kWh 44.4kWh
    Nominal Voltage 488.4Vdc 518Vdc 592Vdc
    Operating Voltage Range 422.4 ~ 545.1Vdc 448 ~ 578.2Vdc 512 ~ 660.8Vdc
    Max. Charge Power 73.2kW 77.7kW 88.8kW @ 2P
    Rated Charge Power 36.6kW 38.8kW 44.4kW @ 1P
    Max. Discharge Power 244.2kW 259kW 296kW @ 6.6P
    Rated Discharge Power 36.6kW 38.8kW 44.4kW @ 1P
    Dimension (W x D x H) 780 x 626 x 1,900 mm 780 x 626 x 2,237 mm
    Weight (Approx.) 565kg 600kg 665kg ±5%

    *The product image is for reference purpose. The actual product may be different (Indicative numbers)
    *Kokam makes no warranty explicit or implied with these specifications. The contents are subjected to change without prior notice.

    Specification

    • Backup Time Up to 6 minutes
    • Model No. 132S
    • Configuration 1P22S x 6
    • Installed Energy 36.6kWh
    • Nominal Voltage 488.4Vdc
    • Operating Voltage Range422.4 ~ 545.1Vdc
    • Max. Charge Power 73.2kW
    • Rated Charge Power 36.6kW
    • Max. Discharge Power 244.2kW
    • Rated Discharge Power 36.6kW
    • Dimension (W x D x H)780 x 626 x 1,900 mm
    • Weight (Approx.) 565kg

    *The product image is for reference purpose. The actual product may be different (Indicative numbers)
    *Kokam makes no warranty explicit or implied with these specifications. The contents are subjected to change without prior notice.

  • 2 Pole – High Power Type

    2 Pole – High Power Type

    Item Specification Remarks
    Backup Time Up to 30 minutes Recommended
    Model No. 132S 140S 160S
    Configuration 1P33S x 4 1P35S x 4 1P32S x 5 Cell: SLPB125255255G1H (85Ah)
    Installed Energy 41.2kWh 43.7kWh 50kWh
    Nominal Voltage 485.7Vdc 515.2Vdc 588.8Vdc
    Operating Voltage Range 422.4 ~ 545.1Vdc 448 ~ 578.2Vdc 512 ~ 660.8Vdc
    Max. Charge Power 82.5kW 87.5kW 100kW @ 2P
    Rated Charge Power 41.2kW 43.7kW 50kW @ 1P
    Max. Discharge Power 242.8kW 257.6kW 294.4kW @ 5.8P, ≤7 min.
    Rated Discharge Power 41.2kW 43.7kW 50kW @ 1P
    Dimension (W x D x H) 580 x 740 x 1,960 mm 580 x 740 x 2,300 mm ±5mm
    Weight (Approx.) 542kg 554kg 658kg ±5%

    *The product image is for reference purpose. The actual product may be different (Indicative numbers)
    *Kokam makes no warranty explicit or implied with these specifications. The contents are subjected to change without prior notice.

    Specification

    • Backup Time Up to 30 minutes
    • Model No. 132S
    • Configuration 1P33S x 4
    • Installed Energy41.2kWh
    • Nominal Voltage 485.7Vdc
    • Operating Voltage Range422.4 ~ 545.1Vdc
    • Max. Charge Power 82.5kW
    • Rated Charge Power 41.2kW
    • Max. Discharge Power 242.8kW
    • Rated Discharge Power 41.2kW
    • Dimension (W x D x H) 580 x 740 x 1,960 mm
    • Weight (Approx.) 542kg

    *The product image is for reference purpose. The actual product may be different (Indicative numbers)
    *Kokam makes no warranty explicit or implied with these specifications. The contents are subjected to change without prior notice.

  • 3 Pole

    3 Pole

    Item Specification Remarks
    Type Ultra High Power High Power Ultra High Power
    Backup Time Up to 6 minutes Up to 30 minutes Up to 6 minutes Recommended
    Model No. 66S+66S 100S+100S UHP Cell: SLPB130255255P (75Ah)
    HP Cell: SLPB125255255G1H (85Ah)
    Configuration 1P22S x 6 1P33S x 4 1P20S x 10
    Installed Energy 36.6kWh 41.2kWh 55.5kWh
    Nominal Voltage ±244.2Vdc ±242.8Vdc ±370Vdc
    Operating Voltage Range ±211.2 ~ 272.5Vdc ±320 ~ 413Vdc
    Max. Charge Power 73.2kW 82.5kW 111kW @ 2P
    Rated Charge Power 36.6kW 41.2kW 55.5kW @ 1P
    Max. Discharge Power 244.2kW 242.8kW* 370kW @ 6.6P, *@5.8P
    Rated Discharge Power 36.6kW 41.2kW 55.5kW @ 1P
    Dimension (W x D x H) 780 x 676 x 1,900 mm 580 x 740 x 1,960 mm 780 x 676 x 2,237 mm
    Weight (Approx.) 580kg 560kg 810kg ±5%

    *The product image is for reference purpose. The actual product may be different (Indicative numbers)
    *Kokam makes no warranty explicit or implied with these specifications. The contents are subjected to change without prior notice.

    Specification

    • Type Ultra High Power
    • Backup Time Up to 6 minutes
    • Model No. 66S+66S
    • Configuration 1P22S x 6
    • Installed Energy 36.6kWh
    • Nominal Voltage ±244.2Vdc
    • Operating Voltage Range ±211.2 ~ 272.5Vdc
    • Max. Charge Power 73.2kW
    • Rated Charge Power 36.6kW
    • Max. Discharge Power244.2kW
    • Rated Discharge Power 36.6kW
    • Dimension (W x D x H) 780 x 676 x 1,900 mm
    • Weight (Approx.) 580kg

    *The product image is for reference purpose. The actual product may be different (Indicative numbers)
    *Kokam makes no warranty explicit or implied with these specifications. The contents are subjected to change without prior notice.

ADVANTAGES

CUSTOMIZATION OF PARALLEL CABINET & RACK CONNECTIONS
Kokam K-UPS battery series provides a modular, easily scalable solution. Kokam batterys unique properties of high energy density and lightweight design allow integration of batteries and UPS battery providing faster and more reliable field installation and start-up.

Provides noticeably longer cycle life and higher power density than lead acid batteries
Minimization of degradation with shallow cycles
Few open-circuit failure modes during normal operation
No hydrogen generation
Integrated monitoring of individual cell’s voltages and temperatures

VRLA (Lead Acid) VS Kokam K-UPS battery

  1. 1
    High Power 5 times more powerful
    VRLA Kokam K-UPS battery
    (>10C-Rate)
  2. 2
    UPS Battery Cycle life Significantly improved
    cycle life
    VRLA
    (MAX 5 years)
    Other Lithium Batteries
    (MAX 10 years)
    Kokam K-UPS battery
    (MAX 15 years)
  3. 3
    Light Weight 5 times lighter
    VRLA Kokam K-UPS battery
  1. 4
    Low Maintenance No Hydrogen gas emissions
    No hydrogen gas emissions reduce ventilation costs and enable safe operation.
  2. 5
    Small Footprint 3.3 times more space efficient
    VRLA Kokam K-UPS battery
  3. 6
    Wide Temperature range No additional cooling system
    VRLA
    (20~22˚C)
    Kokam K-UPS battery
    (18~28˚C)

UPS Battery Cycle life

Up to 15 years warranty guaranteed (Back Up Time Guarantee)

    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    VRLA
    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    6. 6
    7. 7
    8. 8
    9. 9
    10. 10
    Other Lithium Batteries
    1. 0
    2. 1
    3. 2
    4. 3
    5. 4
    6. 5
    7. 6
    8. 7
    9. 8
    10. 9
    11. 10
    12. 11
    13. 12
    14. 13
    15. 14
    16. 15
    Kokam K-UPS battery

Small Footprint : 40% LESS FOOTPRINT, 5 TIMES LIGHTER

VRLA (Lead Acid)

10 Total Rack System Wt. / 66,000 Lbs.
400”W x 30”D = 83.3ft²
2,250kW / 100ft² = 27.0kW/ft²

60 in200 in
Kokam K-UPS battery

8 Total Rack System Wt. / 13,000 Lbs.
280”W x 25”D = 48.6ft²
2,250kW / 48.6ft² = 46.3kW/ft²

50 in140 in

UPS Battery Rack Configuration

2 Pole K-UPS battery

3 Pole K-UPS battery

Fire Suppression & Fan Battery Protection Unit (BPU)
- String BMS
- Switch Disconnector
- Fuse
- Contactor
Switched Mode
Power Supply (SMPS)
Battery Module
(incl. Module BMS)
Rack Cover

2 Pole K-UPS battery

3 Pole K-UPS battery

Fire Suppression & Fan Battery Protection Unit (BPU)
- String BMS
- Switch Disconnector
- Fuse
- Contactor
Switched Mode
Power Supply (SMPS)
Battery Module
(incl. Module BMS)
Rack Cover
HIGHLY SCALABLE AND CUSTOMIZABLE
Kokams UPS battery (K-UPS battery), which is comprised of Kokam’s SLPBs, is lightweight and compact due to its high energy density. It can be placed in small spaces and is easy to maintain due to its convenient accessibility.
Also, when compared to lead acid batteries of the same weight and volume, output performance of Kokam SLPB is significantly higher. Kokams UPS battery can further be classified into two types of backup power systems : short term (minutes) and long term (hours).
KEY STRENGTHS
  • High Power Output
  • Small Volume Footprint
  • Flexible Design
  • Essential backup power to protect critical information and systems
  • Outstanding safety performance
APPLICATIONS

Installed in various locations to provide emergency back-up power during an outage

  • Data center
  • Financial institution
  • Semi-conductor factory
  • Medical facility

CONTACT US

If you are interested in our product, please feel free to contact us

Contact Us

Notice of merger by incorporation into of TAWAKI SRL in SOLAREDGE e-MOBILITY SpA

Please be advised that the documentation relating to the merger plan for the incorporation of TAWAKI SRL in SOLAREDGE e-MOBILITY SpA is available at the registered office and on the corporate website
Taking into account that TAWAKI SRL is a wholly-owned company of SOLAREDGE e-MOBILITY SpA, the merger follow the simplified procedure according to art. 2505 of the Italian Civil Code.
Privacy Statement | Terms of Use /
Copyright ⓒ 2019 Kokam, All rights reserved.